Spectroscopy Camera Solutions

Spectroscopy Cameras for UV to NIR and SWIR

Spectroscopy-based diagnostics in the fields of Material Science, Chemistry, Life Science or Fundamental Physics & Optics rely on the capture and analysis of optical and chemical signatures with a high degree of precision.

Andor portfolio of CCD, EMCCD, InGaAs, ICCD and sCMOS cameras offer tailored solutions to particular sample or optical phenomena detection and characterisation challenges for Raman, Luminescence/Photoluminescence, Non-Linear or Optical Emission Spectroscopy/LIBS –based experiments.

Request Pricing Ask a Question

Spectroscopy Detectors Adapted to your Needs

Andor’s range of detectors offer a wide range of sensitivity, time-resolution and sensor formats to best suit specific experimental conditions from UV to SWIR, nanosecond to hours time resolution, high photon flux to single photon with super dynamic range and resolution. If you are an integrator/OEM please click here.

High Sensitivity & Dynamic Range

  • High sensitivity UV-SWIR
  • Large pixel well depths
  • High resolution matrix
Specifications Request Pricing

ns to µs
Time-Resolution

  • Nanosecond gating
  • High sensitivity down to single photon
  • On-head DDG with ps accuracy
Specifications Request Pricing

kHz Spectral
Rates

  • µs to ms time-resolution
  • High sensitivity down to single photon
  • High resolution matrix
Specifications Request Pricing

Extended Multi-fibre Spectroscopy

  • Large area sensors
  • Ultrafast sCMOS and EMCCD options
  • High sensitivity down to single photon
Specifications Request Pricing

Need Help Selecting the Right Spectroscopy Camera?

Experimental requirements defined by sensitivity/photon flux, wavelength range, acquisition rates, time resolution, spectral and spatial resolution will drive the choice of particular sensor technology over an other. CCD, EMCCD, InGaAs, ICCDs or sCMOS each feature unique attributes. Learn more about each technology here.

Select from the options below to find the detector platform(s) that best meet(s) your needs.

High sensitivity & dynamic range portfolio at a glance...

  iDus CCD Newton CCD Newton EM iDus InGaAs-1.7 iDus InGaAs-2.2
Best suited for • Low UV-NIR photon flux
• Large dynamic range
• Low UV-NIR photon flux
• Fast spectral rates
• Multi-fibre acquisition
• Very low VIS photon flux
• Fast spectral rates
• Multi-fibre acquisition
• Low photon flux & high dynamic range in 1-1.7 µm spectral range • Low photon flux & high dynamic range in 1.7-2.2 µm spectral range
Matrix size (pixels) 1024 x 128
1024 x 256
2000 x 256
1024 x 256
2048 x 512
1600 x 200
1600 x 400
512 x 1
1024 x 1
512 x 1
1024 x 1
Pixel size (µm) 26 or 15 26 or 13.5 16 25 or 50 25 or 50
Peak QE 95% (VIS or NIR) 95% (VIS or NIR) 95% (VIS) 85% (@1.3µm) 70% (@1.8µm)
Min. Cooling (°C) -100 (with UltraVac™) -100 (with UltraVac™) -100 (with UltraVac™) -90 (with UltraVac™) -90 (with UltraVac™)
Min. dark current (e-/pix/s) 0.0004 0.0001 0.00007 10,700 5,000,000
Min. read noise (e-) 3 2.5 <1 (with EM gain) 580 580
Max. register well depth (e-) 1,000,000 1,000,000 1,300,000 170,000,000 170,000,000
Max. spectral rate (sps) 88 1,612 1,515 193 193
Low NIR etaloning option Yes (*) Yes (*) No n/a n/a
Learn more Specifications Specifications Specifications Specifications Specifications
Contact us Request Pricing Request Pricing Request Pricing Request Pricing Request Pricing

(*) Front-illuminated versions have “zero” etaloning, back-illuminated versions with anti-fringing have “low” level of etaloning

ns to µs Time-Resolution portfolio at a glance...

  iStar Intensified CCD iStar Intensified sCMOS
Best suited for • Broadband, ns-µs gated spectra
• High dynamic range [low spectral rates]
• Multi-fibre acquisition
• Narrowband, ns-µs gated spectra
• Fastest spectral rates
• High dynamic range [high spectral rates]
• Fast multi-fibre acquisition
Matrix size (pixels) 1024 x 256
2048 x 512
2560 x 2160
Pixel size (µm) 26 and 13.5 6.5
Peak QE 25% (Gen 2)
48% (Gen 3)
Min. gating speed < 2 ns
Min. read noise (e-) <1 (with MCP gain)
Max. spectral rate (sps) 3,571 4,008
Min. Cooling (°C) -40 0
Min. dark current (e-/pix/s) 0.1 0.18
Max. register well depth (e-) 1,000,000 30,000 (pixel)
Learn more Specifications Specifications
Contact us Request Pricing Request Pricing

kHz spectral rates portfolio at a glance...

  Newton CCD Newton EMCCD iXon EMCCD ZL41 Wave sCMOS Marana sCMOS
Best suited for • Low UV-NIR photon flux
• Fast spectral rates and fast kinetics mode (µs resolution)
• Broadband spectra
• Very low VIS photon flux
• Fast spectral rates and fast kinetics mode (µs resolution)
• Broadband spectra
• Very low VIS photon flux
• Faster spectral rates and fast kinetics mode (µs resolution)
• Narrowband spectra
• Low VIS-NIR photon flux
• Fastest spectral rates
• Narrowband spectra
• Low UV-VIS photon flux
• Fastest spectral rates
• Narrowband / Broadband spectra
Matrix size (pixels) 1024 x 256
2048 x 512
1600 x 200
1600 x 400
512 x 512
1024 x 1024
2560 x 2160
2048 x 2048
2048 x 2048
Pixel size (µm) 26 or 13.5 16 13 or 16 6.5 6.5 or 11
Peak QE 95% (VIS or NIR) 95% (VIS) 95% (VIS) 60% or 82% 95% (VIS)
Min. Cooling (°C) -100 (with UltraVac™) -100 (with UltraVac™) -100 (with UltraVac™) -10 -45 (with UltraVac™)
Min. dark current (e-/pix/s) 0.0001 0.00007 0.00011 0.019 0.1
Min. read noise (e-) 2.5 <1 (with EM gain) <1 (with EM gain) 0.9 1.2
Max. register well depth (e-) 1,000,000 1,300,000 800,000 30,000 (pixel) 85,000 (pixel)
Max. spectral rate (sps) 1,612 1,515 11,074 27,057 24,367
Low NIR etaloning option Yes (*) No No Yes (*) No
Learn more Specifications Specifications Specifications Specifications Specifications
Contact us Request Pricing Request Pricing Request Pricing Request Pricing Request Pricing

(*) Front-illuminated versions have “zero” etaloning, back-illuminated versions with anti-fringing have “low” level of etaloning

Extended multi-fibre spectroscopy portfolio at a glance...

  iKon-M iXon EMCCD ZL41 Wave sCMOS Marana sCMOS iStar 334T iStar sCMOS
Best suited for • Low UV-NIR photon flux
• Fast spectral rates and fast kinetics mode (µs resolution)
• Broadband spectra
• Very low VIS photon flux
• Fast spectral rates and fast kinetics mode (µs resolution)
• Broadband spectra
• Very low VIS photon flux
• Faster spectral rates and fast kinetics mode (µs resolution)
• Narrowband spectra
• Low UV-VIS photon flux
• Fastest spectral rates
• Narrowband / Broadband spectra
• Low UV-VIS photon flux
• Fastest spectral rates
• Narrowband / Broadband spectra
• Low UV-VIS photon flux
• Fastest spectral rates
• Narrowband / Broadband spectra
Matrix size (pixels) 1024 x 1024 512 x 512
1024 x 1024
2560 x 2160
2048 x 2048
2048 x 2048 1024 x 1024 2560 x 2160
Pixel size (µm) 13 13 or 16 6.5 6.5 or 11 13 6.5
Peak QE 95% (VIS or NIR) 95% (VIS) 60% or 82% 95% (VIS) 25% (Gen 2)
48% (Gen 3)
Min. Cooling (°C) -100 -100 -10 -45 -40 0
Min. dark current (e-/pix/s) 0.00012 0.00011 0.019 0.1 0.04 0.18
Min. read noise (e-) 2.9 <1 (with EM gain) 0.9 1.2 <1 (with MCP gain)
Max. register well depth (e-) 150,000 800,000 30,000 (pixel) 85,000 (pixel) 1,000,000 30,000 (pixel)
Max. full image rate (fps) 4.4 26 or 56 100 74 4.2 50
Shuttering Mechanism Mechanical Shutter Frame Transfer Electronic Shutter Electronic Shutter Image Intensifier < 2 ns
Low NIR etaloning option Yes (*) No Yes (*) No n/a n/a
Learn more Specifications Specifications Specifications Specifications Specifications Specifications
Contact us Get Pricing Get Pricing Get Pricing Get Pricing Get Pricing Get Pricing

(*) Front-illuminated versions have “zero” etaloning, back-illuminated versions with anti-fringing have “low” level of etaloning

Applications and Techniques 

Raman Spectroscopy

Raman is a molecular spectroscopy technique that can provides chemical and structural fingerprint information for a wide range of samples, including for example nanomaterials, polymers, powders, liquids or cells/tissues. Key Raman techniques include:

  • Spontaneous and stimulated
  • Surface Enhanced Raman Spectroscopy (SERS)
  • Surface Offset Raman Spectroscopy (SORS)
  • Tip-Enhanced Raman Spectroscopy (TERS)
  • Coherent Anti-Stokes Raman Scattering (CARS)
Contact our application specialists Browse application resources

Absorption / Transmission / Reflection

Ultraviolet Visible Near-Infra red (UV-Vis-NIR) spectroscopy is useful to characterise the absorption, transmission, and reflectivity of a variety of materials such as pigments, biological, coatings, windows, filters, or analyse the dynamics of chemical reactions. Variations of these spectroscopy techniques include:

  • Transient absorption (pump/probe)
  • Diffuse Reflectance
Contact our application specialists Browse application resources

OES and LIBS

Optical Emission Spectroscopy (OES) is a fundamental, non-invasive diagnostic technique for a wide range of plasma, and can provide information such as composition and species temperature and energy distribution.

Laser-induced breakdown spectroscopy (LIBS) is used to determine the elemental composition of various solids, liquids and gases. A high power laser pulse is focused on to a sample to create a plasma. Emission from the atoms and ions in the plasma is collected and analysed by a spectrograph and gated detector to determine the elemental composition or the elemental concentrations in the sample.

Contact our application specialists Browse application resources

Further Reading

Non-Linear Spectroscopy

Non-linear (NL) spectroscopy encompasses a number of optical techniques that can be used to study for example interfacial and surface processes, ultrafast dynamic processes (pump-probe technique), light transport or assist in the understanding of nanoparticles/nanostructures unique optical properties. Key techniques include:

  • Second harmonic generation (SHG) spectroscopy
  • Sum-frequency generation (SFG) spectroscopy
  • Pump-probe transient absorption
  • Coherent Anti-Stokes Raman Scattering (CARS)
Contact our application specialists Browse application resources

Biomedical

Optical spectroscopy can provide very specific analytical information in a non-invasive matter for a range of bio-samples, often as a complement to microscopy imaging (micro-spectroscopy) or visual inspection.

Field of applications include for example cancer cell in vivo and ex vivo screening and cancer diagnostics, non-invasive monitoring of patient bio-parameters or cell sorting.

Contact our application specialists Browse application resources

Plasma Studies

Plasmas can be artificially produced by different means (e.g. laser ablation, coupling of capacitive / inductive power source to ionised gas). The understanding of their properties and dynamics is relevant to a number fields such as fusion, thin films deposition, micro-electronics, material characterization, display systems, surface treatment, fundamental physics, environmental & health.

Gated detectors can be used to determine optical parameters from which fundamental plasma properties can be derived. Accurate nanosecond-scale gating of image intensifier-based detectors can be used to sample plasma dynamics, or to isolate the useful plasma information generated by pulsed lasers.

Contact our application specialists Browse application resources

Spectroscopy Systems, Software and Accessories

Complete your spectroscopy system with Andor’s range of modular spectrograph portfolio, or tailor your camera to best suit your specific application.

Spectrographs and Accessories

  • High modularity, high resolution and high throughput Kymera and Shamrock
  • Large simultaneous bandpass, high resolution Mechelle
Specifications

Spectroscopy Software Solutions

  • Offering rich functionality for data acquisition and processing
  • Control the Andor range of Shamrock spectrographs from your own application
Learn More

Spectroscopy Calculators and Tools

Andor’s range of tools for spectroscopy are designed to assist Researchers with identifying the detection configuration(s) that best matches a given spectroscopy setup requirements from the detector (signal-to-noise ratio comparator) to the spectrograph (spectral resolution and bandpass calculator).

Customer Publications