Resources
The most sensitive EMCCD spectroscopic detector ever offers you active pixels of 1600 x 400 along with 16 x 16 µm pixel size along with the -100°C TE cooling. It’s variable readout rates enable data readout at up to 3 Megahertz, through the plug and play USB interface.
EM technology enables charge from each pixel to be multiplied on the sensor before readout, providing single photon sensitivity. The Newton EM platform combines a 1600 x 200 (or 1600 x 400) array of 16 µm pixels, thermoelectric cooling down to -100°C for negligible dark current, 3MHz readout and USB 2.0 plug-and-play connectivity to provide unrivalled performance for spectroscopic applications. The dual output amplifiers allow software selection between either a conventional High Sensitivity or Electron Multiplying outputs to suit a broad range of photon regime conditions. This makes the Newton EMCCD the ideal choice for ultrafast chemical mapping applications e.g. SERS, TERS or luminescence mapping.
EM sensor technology - <1e- read noise
Fringe suppression technology as standard (970-BVF only) - Fringing minimized for NIR applications
Multi-Megahertz Readout - High repetition rates achievable with low noise electronics
TE cooling to -100°C - Negligible dark current without the inconvenience of LN2
UltraVac™ - Permanent vacuum integrity, critical for deep cooling
16 x 16 µm pixel size - Optimized pixel size for achievement of high resolution
Dual output amplifiers - Software select between either a conventional High Sensitivity output (for low light applications) or an Electron Multiplying output (for single photon sensitivity
Crop Mode Operation - Achieve the highest possible spectral rates of over 1,500 spectra per second
Simple USB Connection - USB connection direct from back of camera – no controller box required!
Solis software for Spectroscopy - Comprehensive, user-friendly interface for simultaneous detector & spectrograph control
Software Development Kit (SDK) - Ease of control integration into complex setups: Matlab, Labview, Visual Basic or C/C++
ACC-6MM-TUBING-2xxxxM - 6 mm tubing option for ACC-XW-CHIL-16
ACC-SD-VDM1000 - Shutter Driver for NS25B Bistable Shutter (not needed for Shamrock spectrographs)
ACC-SHT-NS25B - Bistable Shutter, Standalone (not needed for Shamrock spectrographs)
ACC-6MM-TUBING-2X2.5 / ACC-6MM-TUBING-2X2.5 - 2.5 and 5 m black hose options to chiller/recirculator
LM-C - C-mount lens adaptor
LM-NIKON-F - F-mount lens adaptor
LMS-NIKON-F-NS25B - Nikon F-mount lens adaptor with shutter
XC-CHILLER-AL - Ultra Compact Chiller Unit, Thermo-Electric based cooling technology
XC-COOL-HOSE_BARB-06 - Chiller and recirculator hose kit, 100 cm clear hose with fitted valved male/female connectors (chiller or recirculator side), spare male/female un-valved connectors (for hose extension ACC-6MM-**** black hose options)
XC-COOLANT_702-070L - 700 mL Propylene Glycol with corrosion and biological inhibitors