Resources
Andor’s new iDus 416 platform boasts a unique combination of very low dark noise and very high QE, offering unrivalled sensitivity in the near-infrared. This makes it the ideal detector for NIR Raman and Photoluminescence, reducing greatly acquisition times and removing the need for inconvenient LN2 cooling.
The unique 2000 x 256, 15 µm pixel array allows extended, broadband and high resolution spectral acquisition, while the fringe suppression technology virtually eliminates the optical etalonning at the higher wavelengths.
With its compact form factor and USB 2.0 connectivity, the iDus 416 can be seamlessly integrated to Shamrock USB 2.0 spectrographs and controlled from a laptop. Andor’s UltraVac™ technology carries a unique track record when it comes to performance and reliability, maintaining superb performance year after year for both Research users and industrial integrators.
Low dark current - 10x better than Back-Illuminated Deep-Depletion NIMO sensors, best SNR in the NIR.
Peak QE up to 95% - Best detection capability in the NIR.
15 µm pixels - Ideal for high resolution spectroscopy.
30 mm wide sensor - Superior simultaneous band-pass capture
Fringe suppression technology as standard - Optical etalonning virtually eliminated.
TE cooling down to -95°C - Critical for elimination of dark current detection limit - no inconvenience associated with LN2
Ultravac™ - Critical for sustained vacuum integrity and to maintain unequalled cooling and QE performance year after year.
USB 2.0 connection - Ideal for laptop operation.
Compact and rugged platform - Ideal for OEM integration & laboratory setups.
Solis software for Spectroscopy - Comprehensive, user-friendly interface for simultaneous detector & spectrograph control
Software Development Kit (SDK) - Ease of control integration into complex setups: Matlab, Labview, Visual Basic or C/C++
ACC-6MM-TUBING-2xxxxM - 6 mm tubing option for ACC-XW-CHIL-160
ACC-6MM-TUBING-2X2.5 / ACC-6MM-TUBING-2X2.5 - 2.5 and 5 m black hose options to chiller/recirculator
ACC-SD-VDM1000 - Shutter Driver for NS25B Bistable Shutter (not needed for Shamrock spectrographs)
ACC-SHT-NS25B - Bistable Shutter, Standalone (not needed for Shamrock spectrographs)
LM-C - C-mount lens adaptor
LM-NIKON-F - F-mount lens adaptor
LMS-NIKON-F-NS25B - Nikon F-mount lens adaptor with shutter
XC-CHILLER-AL - Ultra Compact Chiller Unit, Thermo-Electric based cooling technology
XC-COOL-HOSE_PLUG-06 - Chiller and recirculator hose kit, 100 cm clear hose with fitted inserts (camera side) and valved male/female connectors (chiller/recirculator side), spare male/female un-valved connectors (for hose extension ACC-6MM-**** black hose)
XC-COOLANT_702-070L - 700 mL Propylene Glycol with corrosion and biological inhibitors
XC-RECR-AL - Coolant re-circulator for deeper-cooling performance