The ultimate limit to analytical sensitivity is the reliable detection of single molecules. Recent technical advances in optical detection and manipulation have made the detection of isolated, light emitting probe molecules a reality. Thus we are witnessing a burgeoning interest in the imaging and spectroscopy of single molecules, particularly within the fields of cell biology and drug discovery. Of particular importance to biology is the possibility of direct, real-time visualization of single biological macromolecules and their assemblies under native physiological conditions, offering great promise for enhancing our understanding of the behaviour, interactions, mechanisms and trafficking of individual biological macromolecules within the living cell. Studies using techniques such as STED, STORM, PALMIRA and SRRF-Stream have increasing medical and pharmaceutical significance within the developing post-genomic era of proteomics, providing the means to track the behaviour, kinetics and mechanistic involvement of biochemically relevant single proteins, such as enzymes.
It is reasonable to ask why it is interesting to observe the emission from a single fluorophore, since numerous fluorophore labels can be detected within a diffraction-limited spot. There was a time when the scientific community was content with detecting the combined signal of a vast number of fluorescent (or Raman active) molecules from a point of interest within the sample. There is a rapidly growing realization however, particularly within the life and materials science fields, that the information content afforded by imaging the single fluorophore markedly exceeds that offered by the "bulk" ensemble measurement, yielding invaluable insight into individual molecular properties and their micro-environment. Experiments on single molecules have attracted vivid interest in many branches of fundamental research because they allow for the study of molecular properties normally disguised in inhomogeneous distributions of an ensemble. In contrast to observing the position of several labeled molecules at a given position, single molecule detection provides additional information, such as:
Single molecule studies are uniquely poised to yield information about molecular motion, behaviour, and fluctuations over time and space. There are many biological molecules that can avail from examination at this level, typical subjects being key members of a system that are receptive to:
What processes are typically studied using single molecule experiments?
Single molecule detection is a way to study detailed physical and chemical properties that allows for scrutiny of fundamental principles and mechanisms, and may lead to technological and methodological developments. Single molecule techniques also have key potential in material development. The single molecule is an excellent probe of local (nanoscale) properties since it is a quantum light source with spectrum and lifetime that is sensitive to its chemical and physical environment. The rotational and translational motion of single molecules can be measured and used to understand the local mechanical properties of the material in which the molecules are embedded. Thus, research groups are seeking to understand and catalogue the great variety of behaviours of single molecules in technologically relevant environments to better use these probes to study the small-scale structure. An important aspect of these studies is a highly sensitive means to detect photons which are by the very nature of these techniques at a very low level. For this reason EMCCD detectors such as the iXon EMCCD are used. To find out more about the suitability of different cameras for use in Single Molecule Studies please refer to the article: What is the best Detector for Single-Molecule Studies.