Part of the Oxford Instruments Group
Expand

OptistatDN-V

A 77 K nitrogen bath, sample-in-vacuum cryostat.

  • 77 K - 500 K temperature range

  • Large sample space

  • Long cryogen hold time


Request Pricing Add to quote list

  • 77 K- 500 K temperature range
  • Cooling to 77 K in about 20 minutes
  • Long cryogen hold time, around 15 hours, providing a full working day's operation
  • Large sample space for studying samples with a wide range of size and geometry
  • Minimal number of windows in the optical path, reducing reflective losses
  • Superb optical access (f/1) for measurements requiring light collection
  • Large illumination area, 35 mm diameter window aperture
  • Configured for reflectance and transmission measurements
  • Compact size allowing easy integration into commercial spectrometers
  • Measurement-ready, via 10-pin electrical wiring to the sample
  • Supplied with a MercuryiTC temperature controller
  • 1 year standard warranty

Low cryogen consumption: Brings significant benefits in terms of running cost

Quick experiments: A range of sample holders and probes, including liquid cuvettes sample holders and height adjust/rotate probes, are available

Simple: The experimental windows and sample holders can be easily changed

Versatile: A range of window materials are available. Please contact your local sales representative for more information

Software control: Oxford Instruments electronics products are controllable through the software using RS232, USB (serial emulation), TCP/IP or GPIB interfaces. LabVIEW function libraries and virtual instruments are provided for Oxford Instruments electronics products to allow PC-based control and monitoring. These can be integrated into a complete LabVIEW data acquisition system

Temperature range: 77.2 to 500 K

Temperature stability: ± 0.1 K

Liquid nitrogen hold time: 15 hrs at 77 K (nominal)

Room temperature to base temperature: approx. 20 min

Weight: 5 kg

A typical system comprises of:

  • Cryostat
  • Temperature Controller
  • Accessories and Manuals
  • Software

UV / Visible spectroscopy: Experiments at low temperatures reveal the interaction between the electronic energy levels and vibrational modes in solids.

Infrared spectroscopy: Low temperature IR spectroscopy is used to measure changes in interatomic vibrational modes as well as other phenomena such as the energy gap in a superconductor below its transition temperature.

Raman spectroscopy: Lower temperatures result in narrower lines associated with the observed Raman excitations.

Photoluminescence: At low temperatures, spectral features are sharper and more intense, thereby increasing the amount of information available.

You may also be interested in...

Related Applications

Nanomaterial Growth and CharacterisationCharacterisation of Low Dimensional StructuresModular Optical Spectroscopy