Part of the Oxford Instruments Group
Expand

Mechelle 5000 Spectrograph

Andor’s new Mechelle ME5000 Echelle spectrograph has been designed to provide simultaneous recording of a wide wavelength range (200-975 nm) in one acquisition. It has no moving components is available in a pre-aligned detector/spectrometer format.

  • Compact and robust design
  • Patented optical design
  • Auto-temperature correction
  • N2 purged
  • Pre-aligned detector/spectrograph


Request Pricing Ask a Question Add to quote list

Andor’s new Mechelle ME5000 Echelle spectrograph has been designed to provide simultaneous recording of a wide wavelength range (200-975 nm) in one acquisition. It has no moving components is available in a pre-aligned detector/spectrometer format. The Andor Mechelle spectrograph is based on the echelle grating principal and its patented optical design provides extremely low cross-talk and maximum resolution compared with other spectrographs.

Compact and robust design with no moving components - Ideal for non-lab based applications

Patented optical design - Ensures maximum resolution and extremely low cross-talk

Auto-temperature correction - Corrects for the variation of prisms optical refractive index with temperature

N2 purged - Enables maximum throughput in the UV region

Pre-aligned detector/spectrograph solution - Enables fast, efficient experimental set-up

Low F/number - Highly efficent light collection

Wide range of accessories available - Including fibre optics, slits, aiming Laser, collector/collimator and calibration lamps

Andor Solis software - Extracts automatically a full wavelength calibrated spectrum from a complex echelle image and offers system advanced data manipulation capabilities

Peak labelling with NIST table - Easy tagging of known atomic species at the press of a button

Upgrades/Accessories

ACC-LK-HGAR-OCE - Mercury-Argon calibration lamp with SMA connector  

LK-DHRD-OCE-CAL - Deuterium-Halogen lamp, radiometrically calibrated (230 to 1,050 nm)

ME-OPT-0007 - UV-NIR light collector / collimator with laser module for F/# = 2 collection

ME-SHT-9002 - Mechelle shutter unit (recommended when using iKon-M DU934P-yy-9FL)

ME-SLT-25x25 - Mechelle 25 x 25 µm slit

ME-SLT-10x50 - Mechelle 10 x 50 µm slit

ME-SLT-50x25 - Mechelle 50 x 25 µm slit

ME-SLT-25x50 - Mechelle 25 x 50 µm slit

ME-SLT-50x50 - Mechelle 50 x 50 µm slit

ME-SLT-100x50 - Mechelle 100 x 50 µm slit

ME-SLT-200x50 - Mechelle 200 x 50 µm slit

Related Applications

Nanomaterial Growth and CharacterisationIdentification of Contaminants in Food Production and SoilMeasurement of Chemical and Molecular CompositionMaterials for the Power Generation IndustryGunshot Residue AnalysisForensic Soil Analysis and Other Trace AnalysisAnalysis of Environmental ContaminantsMaterial Composition and StructureCharacterisation of Low Dimensional StructuresFabrication and Characterisation of Light Emitting DevicesModular Optical SpectroscopyRock Core Analysis