Part of the Oxford Instruments Group
Expand

Webinars

Piezoresponse and Electrochemical Force Microscopy and Spectroscopy | Virtual Academy by Asylum Research - Group

Published: 29 Aug 2024 · Last updated: 29 Aug 2024

Asylum Research recently hosted a virtual academy on Piezoresponse and Electrochemical Force Microscopy and Spectroscopy. The academy was organized by renowned leaders in the field, Sergei V. Kalinin and Roger Proksch, and features lectures from experts around the world. The introductory keynote lecture was given by Prof. Andrei Kholkin of the University of Aveiro, a prominent figure in the field of ferroelectric materials and measurement technologies.

The PFM Academy aimed to provide a comprehensive introduction to the field, covering recent developments and integrating the latest advances with established theory and practice. This especially benefits newcomers to the field of ferroelectrics with learning about advances in material analysis, including binary ferroelectric materials like hafnia and nitrides, twisted bilayers, and layered ferroelectrics. On the instrumental side, the academy explored new interferometric detection systems for quantitative measurements of electromechanical properties, as well as machine learning and automated experiments for analyzing large PFM datasets.

The virtual academy followed the tradition of the PFM schools that began in 2006 at ORNL. The curriculum consists of two hours of virtual lectures, held twice a week over a five-week period, allowing attendees to tailoring your learning to your specific needs.

We believe it is important to ensure this highly valuabe learning resouce remians accessible, and so all these lectures are available to watch on-demand.

Curriculum Outline

Virtual PFM Academy - Day 1

  • History and principles of PFM: from the discovery to materials investigation (Andrei Kholkin)
  • Single frequency PFM (Seungbum Hong)
  • Cantilever dynamics and detection modes in SPM (Roger Proksch)

Day 1 - Watch on demand

Virtual PFM Academy - Day 2

  • Spectroscopic modes in piezoresponse force microscopy (Rama Vasudevan)
  • Theory of PFM image formation mechanism (Sergei Kalinin)

Day 2 - Watch on demand

Virtual PFM Academy - Day 3

  • PFM domain manipulation (Nina Balke)
  • PFM and related imaging modes on improper and uniaxial ferroelectrics (Marty Gregg)

Day 3 - Watch on demand

Virtual PFM Academy - Day 4

  • PFM of hafnia and binary ferroelectrics (Yunseok Kim)
  • SPM of ferroic halide perovskite optoelectronics (Yongtao Liu)

Day 4 - Watch on demand

Virtual PFM Academy - Day 5

  • PFM of layered materials (Elzbieta Gradauskaite)
  • PFM of relaxor ferroelectrics (Vladimir Shvartsman)

Day 5 - Watch on demand

Virtual PFM Academy - Day 6

  • PFM of biological systems (Brian Rodriguez)
  • PFM across frequencies in liquids (Nina Balke)

Day 6 - Watch on demand

Virtual PFM Academy - Day 7

  • Introduction to Electrochemical Strain Microscopy (Denis Alikin)
  • ESM theory and applications (Anna Morozovska)

Day 7 - Watch on demand

Virtual PFM Academy - Day 8

  • “False PFM”: Indications of false piezoelectric signals, and the influence of the environment (Rama Vasudevan)
  • PFM data analysis with machine learning (Richard Liu and Yongtao Liu)

Day 8 - Watch on demand

Virtual PFM Academy - Day 9

  • Using GitHub and software ecosystems to increase collaboration and generate reproducible science (Rama Vasudevan)
  • Building Automated experiment in the lab (Boris Slautin, Yongtao Liu, and Richard Liu)

Day 9 - Watch on demand

Virtual PFM Academy - Day 10

  • Automated experiments in PFM - structure-property mapping (Yongtao Liu, Richard Liu, and Boris Slautin)
  • Automated experiments in PFM - combinatorial libraries (Yongtao Liu, Richard Liu, and Boris Slautin)

Day 10 - Watch on demand

← Back to Learning