X-Nuclei NMR Spectroscopy Part 2: Broadband Nuclei analysis with X-Pulse
— Technical Article IntroductionNMR spectroscopy is most commonly used to analyse hydrogen-1 (1H, proton), carbon-13 (13C) and fluorine-19 (19F) nuclei. However, most modern NMR spectrometers can observe many more nucle…
Myeloid Therapy: High-Resolution Insights into Brain Rescue
— Webinars
Many neurodegenerative diseases share a common driver: the failure of the brain’s immune system. This research uncovers a pre-symptomatic "interferon alarm" that triggers progressive decline and ide…
Extending SEM X-Ray Analysis with BEX: A Solution to X-Ray Shadowing
— Application Notes What is X-ray Shadowing and How Does It Limit SEM-EDS Analysis
The study focuses on the chemical characterisation of particulate material captured by an in-line liquid
chromatography filter, where …
TD-NMR vs NMR Spectroscopy and Other Complementary Methods
— Application Notes Time-domain nuclear magnetic resonance (TD-NMR) is a low-field NMR technique that is commonly used in quality assurance and quality control (QA/QC) across food, agriculture, petroleum, polymer and ot…
Importing Objects into the Cell Module as a Workflow
— Tutorials Discover how to import objects into the Cell module within a Workflow to streamline cell-based analysis and maintain
consistency across multiple datasets.
Object-Based Colocalization Options in Workflow
— Tutorials
Learn how to use the Object-Based Colocalization options within a Workflow to analyze spatial relationships between
detected objects and generate reproducible results across similar datasets.
Statistic Export Options
— Tutorials
This tutorial demonstrates how to use the Statistics Export options in Workflows to efficiently save, organize, and
review your analysis results for downstream processing and reporting.
10 things you didn’t know about EMCCD Cameras
— Technical Article Charge-coupled device (CCD) cameras laid the foundation for modern scientific imaging and defined standards for sensitivity and image quality across microscopy and spectroscopy for decades. This incl…
Exceptional Environmental Control on Cypher and Vero AFMs
— Application Video
The ES and VRS1250 models in the Cypher and Vero AFM families are designed from the ground up for exceptional environmental control. They are based on a fully sealed, pressure‑t…
Scanning Capacitance Microscopy
— Application Video
Scanning Capacitance Microscopy (SCM) is a powerful electrical characterization technique with broad applicability across a variety of fields such as semiconductors, failure ana…
Fast Moiré Imaging with the Jupiter Discovery
— Application Video
Imagine doing AFM, only many times faster. In an hour, you could collect a complete dataset that would normally take
a week with conventional AFMs. See the difference in speed with Oxford Instrume…
Asbestos Analysis in the SEM with AZtecAsbestos
— Application Notes Introduction: Why is asbestos analysis crucial?
Asbestos is a material that was widely used in the mid-late 20th century as an insulator (in buildings, boilers, pipes, roofing a…
Ultra-Sensitive Blue & UV Detection with the iXon Ultra Blue EMCCD
— Application Video Join Colin Coates as he goes through the iXon Ultra Blue EMCCD, exploring its advanced design, ultra-sensitive blue
and near-UV performance, and enhanced quantum efficiency. He explains how these c…
What Makes Vero AFMs Different?
— Application Video What makes the Vero AFM different from most other AFMs? Unlike conventional AFMs that must infer height from angular changes of the cantilever, the Vero AFM uses an interferometric detector to direc…
Distribution and Identification of Nanoparticles in Cells using EDS
— Application Notes Aim
To confirm the uptake and the subcellular localisation of thallium nanoparticles in cells and tissues for cancer therapy.
Challenge
When investigating the localisation of nanoparticles with el…
RISE Microscopy for 2D Materials
— Webinars
Due to their unique optical and electronic properties, two-dimensional (2D) materials have great potential for application in optoelectronic devices, sensors energy storage, cat…
Photonics and Optical Detectors - A to Z Glossary
— Technical Article
A
B
C
D
E
F
G
L
N
O
P
Q
R
S
T
U
W
X
Z
What is Accumulation?
Accumulation is the process by which data acquired from a number of similar scans are added together in computer me…
KPFM Made Simple
— Application Video
Kelvin Probe Force Microscopy (KPFM) is an AFM imaging mode which maps the work function of a sample surface while simultaneously imaging its topography. Many users could benefi…
Electrolyte Analysis with the X-Pulse
— Application Notes Introduction
There is a growing importance in the use of automation in laboratory environments, for example the use of Materials Acceleration Platforms (MAPs), automating both experiments and subseq…
Graphene Cutting Using Anodic Oxidation Lithography
— Application Video
Watch how easy it is to cut graphene with AFM using anodic oxidation lithography, a standard feature in our software. Graphene cutting can be used to make twisted bilayer graphe…
Andor CB2 Series Webinar
— Webinars
Andor CB2 camera series is a brand new family of sCMOS cameras, designed to deliver outstanding performance and flexibility for advanced imaging applications.
In this webinar, …
Performance Testing Andor's Marana 4.2B-11 sCMOS Camera
— Application Notes Based on Apergis et al. 2025, RASTI, 4, rzaf049
Complementary Metal–Oxide Semiconductor (CMOS) image sensors have been developed in parallel with Charge-Coupled Devices (CCDs) for decades, but…
Developments in Infrared e-APD Wavefront Sensing Camera Technology
— Technical Article The planet-hunting astronomical instruments of tomorrow, which aim to discover Earth-like planets in nearby star systems by 2035, must be capable of delivering image contrast of order 109. Rapid and …
Automated Microparticle Analysis with ParticleScout and Raman Microscopy
— Application Notes
High-resolution measurements of particles are of great interest in many fields of application. Oxford Instruments' ParticleScout is an analysis tool for witec360 Raman microscopes that locates, cat…
RISE Microscopy for Pharma Research
— Webinars
The development and production of drug delivery systems requires efficient and reliable control mechanisms to ensure the quality of the final products. These products can vary w…
Simple Automated Surface Roughness Measurements
— Application Video
Surface roughness is one of the most common measurements made with AFM. While very useful, they can become tedious and time consuming when they need to be made repeatedly on mul…
A Graphical Guide to (EM)CCD Frame Rates and Readout Latency
— Technical Article Achieving high frame rates and minimising data transfer latency is necessary in many experiments and instruments that incorporate scientific imaging cameras. Frame rate is the speed at which consecut…
Optical Diagnostics to Empower Fusion Reactor Development
— Application Notes Energy security is becoming increasingly important from both a civilian and national defense perspective. From a civilian point of view, energy resilience is coming under threat from the rise of AI c…
Dendritic Spine Segmentation
— Tutorials
In this tutorial, learn three methods for dendritic spine segmentation in Imaris 11.0: manual drawing and editing, automatic detection in the Filament wizard, and automatic dete…
Dedicated, Comprehensive and Fast Mineral Analysis with AZtecGeo
— Application Notes Electron microscopists and geoscientists have worked together to refine workflows for efficient whole-sample mineralogical characterisation. This collaboration led to the adaptation&nb…
Measuring Fat Content of Dairy Products by NMR
— Application Notes Method
A variety of dairy products with a range of fat contents between 1% and 82% were analysed by NMR using an MQC-23 fitted with a 26 mm hydrogen probe. Analyses were conducted using the EasyCal …
Confocal Raman Imaging and Correlative Techniques in Life Science
— Application Notes Confocal Raman microscopy is a label-free and non-destructive technique that enables 2D and 3D measurements on biological samples both in vivo and in vitro. It can be seamlessly combined with other t…
Include a Manual Step in the Batch Analysis
— Tutorials
Do you have an image analysis process that’s almost entirely automated, except for one step that must remain manual? Do you still want to run your analysis in Batch mode t…
Use and Adjust an existing Workflow
— Tutorials
Workflows can be created and shared with your colleagues and other researchers. You can also request a Workflow setup from our Technical & Application Support Team. In this …
Set Up, Execute and Share a Workflow
— Tutorials
In this tutorial, you will learn how to organize your image analysis into Workflows. These Workflows can be exported and reused to efficiently analyze other similar images with …
Routine Moiré Imaging of Twisted 2D Materials
— Application Video
Many AFM manufacturers show moiré images of twisted 2D materials, but it is not evident how long these images take to acquire. Oxford Instrument's hi…
Raman Knowledge Base
— Technical Article Raman Basics
How is the spatial resolution defined?
The spatial resolution of a conventional wide-field as well as a confocal microscope is influenced by the numerical aperture (NA) of the objectiv…
Scintillators for Andor High Energy Detection Cameras
— Application Notes iKon-L HF CCD
Best Resolution
Best Throughput
Scintillator Characteristics
Spatial Resolution*
Energy Range
Scintillator Characteristics
Spatial Resolution*
Energy Range
YAG;…
RISE Microscopy for Biomineralization Studies
— Webinars
Over the years biominerals have been refined by natural selection, leading to the unique forms and functions we observe today. These forms can be studied at high resolution usin…
Andor Solutions for Situational Awareness
— Solution Note Surveillance systems are critical to the operation of modern security services, providing situational awareness that supports strategic planning and tactical decision making alongside accurate detect…
Torsional Force Microscopy of Twisted 2D Materials
— Application Video
Determining the twist angle of stacked 2D materials by imaging the moiré periodicity is a critical step in the fabrication and characterization of these materials. But so…
Energy Transfer in Quantum Dots
— Application Notes Solid-state light-emitting diodes (LEDs) emit nearly monochromatic light, yet seamless tuning of emission color throughout the visible region remains elusive. Color-converting powder phosphors are th…
Airborne SWIR Imaging for Surveillance and Situational Awareness
— Solution Note Modern security and surveillance technology is relied upon to deliver increasingly accurate situational awareness while remaining dynamic and autonomously adaptable in the field. As a result, airborn…
Mechanical Microscopy of Surface Treatments
— Application Notes Surface treatments, such as coatings, nitriding, and shot peening, are invaluable to industry as a method to improve the functional and mechanical behavior of parts without changing the primary mater…
In-Situ, High-Temperature Microcompression of Silicon
— Application Notes High temperature microcompression is an exciting application that allows uniaxial stress-strain behavior to be measured as a function of temperature for site-specific microstructural features: grains…
Mechanical Microscopy of Additively-Manufactured 316L Stainless Steels
— Application Notes Additive manufacturing of metal components is changing the way components are both designed and manufactured due to its capability to make complex geometries. However, additively-manufactured materia…
Adhesion Measurement via Nanoindentation
— Application Notes Modern products increasingly utilize engineered surface functionalities to achieve superior performance, such as hydrophobicity for self-cleaning window glass. These properties result from tailored s…
Strain Rate and Nanoindentation
— Application Notes The deformation behavior of materials is often time dependent. During uniaxial mechanical testing at higher deformations speeds, most metals display higher strengths. This time dependence is called s…